Ions that could not be transported by a hose or metal tube in the past are now possible to remove static electricity even where a static eliminator cannot be installed. A small high-voltage power supply is built in. A low-voltage DC power supply can be used. No special high-voltage power supply or high-voltage wiring is required , There will be no high-voltage failure of the exposed wiring, and it can accurately perform point-like static elimination on the target point
136-8893-6840 National Service Hotline: 136-8893-6840 Inquire Now
In addition to static ion wind snake LSD-460 In addition to static ion wind snake LSD-460 In addition to static ion wind snake LSD-460 In addition to static ion wind snake LSD-460
除静电离子风蛇LSD-460

Product manual

除静电离子风蛇LSD-460
除静电离子风蛇LSD-460
除静电离子风蛇LSD-460
除静电离子风蛇LSD-460

Product features

Ions that could not be transported with a hose or metal tube in the past are now possible.
* Static elimination can be performed even in places where the static eliminator cannot be installed.
Built-in small high-voltage power supply, can use low-voltage DC power supply.
* No special high-voltage power supply or high-voltage wiring is required, and no high-voltage failure of exposed wiring will occur.
It can accurately perform point-like static elimination on the target point.
* Because the product can be accessed with a hose or metal tube, the target point can be quickly neutralized.
* The minimum distance to the charged body is only 1mm, and the distance can be adjusted.
With excellent ion balance, it can remove static electricity for a long time.
* At a distance of 200mm, the decay time from ± 1000V to ± 100V is less than 1S. (When using a standard nozzle or a muffler nozzle, 0.3Mpa is applied.)
An alarm is output when an abnormality occurs in the high-pressure system that generates ions.
* The red light indicates the abnormal operation indicator for static elimination, and the green light indicates the normal operation indicator for static elimination.
Choose from a variety of mouthpiece accessories.
* Select a reasonable nozzle according to the requirements of static elimination to make it more effective.
* It is also possible to design the nozzle when it is at the customer's site according to the requirements and usage conditions.
Inductive nozzle-electrically synchronized.
* It is more suitable for assembly line operation, easy to manage and save gas source.
* The sensing distance can be adjusted according to the characteristics of the product (up to 1m)

Product parameter

Product number LSD-460
Input power voltage DC24V
Consumption current 200mA
LED indication Static elimination operation indicator Static elimination operation is normal, green indicator light is on
Static elimination operation abnormal indicator In addition to the abnormal operation of static electricity, the red indicator light is on
Use airflow Air (clean air without moisture or oil)
Air pressure use range 0.05-0.5Mpa
Use ambient temperature 0-40 ° C (no condensation)
Use of ambient humidity 30-70% RH (no water condensation)
Ion generation method High frequency AC corona discharge method
Ion balance Automatic Ionic Pinnacle System 0 ± 10V
Ozone concentration 0.037ppm or less
Piping connection diameter ø6 trachea
Size (mm) 94 * 49 * 27
Weight (kg) 0.15
Filtration accuracy 0.1µm
Filtration efficiency 99.9%
Elimination test conditions
Operating voltage: DC24V Test voltage: ± 1000V- ± 100V Ambient temperature 23 ℃ ± 2 ℃
distance 200mm 300mm
Static elimination time positive 0.7s 1.1s
negative 0.9s 1.3s
Residual voltage positive <0 ± 10V
negative
Note :
1. The measurement method is: use 20PF, 150mm diameter static elimination monitor, and measure according to our company's measurement conditions.
2. Static elimination time refers to the decay time from ± 1000v to ± 100v when no filter is installed and the air volume is large.
The distance is from the center of the air outlet.
Accessories specifications
model material Weight (g) Surface treatment
filter H80604 Aluminum alloy 8.6 Natural anodizing
Shower nozzle H80012 SUS304 5 "——"
Tracheal nozzle H80568 SUS304 5.4 "——"
Standard nozzle H80013 Aluminum alloy 1.6 Natural anodizing
Flat nozzle H80749 SUS304 9 "——"
Silencer H80738 SUS304 7.75 "——"

Online message ONLINE MESSAGE

-National Service Hotline-

136-8893-6840

Inquire Now

Online message

  • Name: *
  • phone: *
  • mailbox:
  • leave a message:
  • Verification code: * Verification code

Core Products Recommended

东莞市龍氏逹除静电电器科技有限公司版权所有备案号: 粤ICP备16056540号-1 Baidu Statistics [Background Management] Dongguan Longshiyao Static Electric Appliance Technology Co., Ltd. All rights reserved Record number: 粤 ICP 备 16056540 号 -1
炸金花 炸金花 炸金花 炸金花